Description of product: Grove - 2-channel solid state relay
Module from the Grove series with 2-channel relay SSRwith control voltage of5 V and rated voltage of contacts of240 V AC and 2 A. Due to the application ofsemiconductortechnology, the relay has no mechanical contacts which positively affects the service life of the equipment. The lack of contacts meansno noiseduring switching. The kit consists of a Grove cable and acrylic case.
Grove - 2-channel solid state relay
Relay from Grove is based onhigh quality G3MC202P module that allows you to use5 V DCfor control ofmax. 240 V AC. The module hastwo channels which can be controlled separately. Thanks to the Grove interface, the module can be operated in a simple and easy way using Arduino.
The product is compatible withArduinoandRaspberry Pi Manufacturer has prepareda user manualalong with a model program forArduinoandRaspberry Pi. |
Features and application of 2-channel solid state relay from Grove
The advantages to mechanical relay:
- Completelysilent operation.
- The lack of physical contact which meansno sparks.
- Extended lifespan.
- Compact and thin-walled design SSR.
Disadvantages in relation to the mechanical relay:
- After closing, there is the higher resistance (heat generation).
- Increased electrical noise.
- Works only for AC loads.
The use of solid state relays:
- During operations that require switching with the low delay, for example, a phased inspection of light
- Devices that require high stability, such as medical devices.
- Situations requiring protection from explosion, stain, resistant to moisture, such as coal industry, chemical industry.
Grove - 2-channel solid state relay in an acrylic case.
Wiring of the Grove relay
The module is equipped with Grove interface facilitating its connection tothe Arduinoalong with Base Shield v2.0using the supplied cable.
Pin | Description |
---|---|
1. CTR1 | Input control signal for switch 1. |
2. CTR2 | Input control signal for switch 2. |
3. VCC |
The power of the module is 5 V. |
4. GND | The ground of the system. |
5. Load 2 | One port of the switch # 1 for connecting to the cable of the load. |
6. Load 1 | The second switch port number 1 to connect the cable of the load. |
7. Load 2 | One port of the switch no. 2 to connect the cable of load. |
8. Load 1 | The second port of the switch no. 2 to connect the cable of the load. |
Technical specification of the Grove module with 2-channel solid state relay
Option | Range |
---|---|
Input working voltage | from 4 V to 6V |
Rated input voltage | 5 V |
Rated load voltage | 100 V to 240 V AC 50/60 Hz |
Load voltage range | from 75 V to 264 V AC from 50/60 Hz |
Load current | from 0.1 A to 2 A on switch |
Leakage current | 1.5 mA max. (at 200 VAC) |
Insulation resistance | 1,000 MΩ min. 500 V DC |
Working temperature | from - 30°C to 80°C |
Input interface | Digital |
Set includes |
|
Useful links |