- EOL
Attention! The product has been discontinued. Check other products in category. |
Product description: SenseCAP SOLO CO2 5000 - CO2 concentration sensor - NDIR - MODBUS-RTU RS485 and SDI-12 - Seeedstudio 101990669
DigitalCO2 concentration sensor, which operates on the basis of non-dispersive NDIR technology. A non-dispersive sensor, which means that there is no element that splits light into its components. The measuring range is from 400 ppm to 5000 ppm. The module supports Modbus (Modbus-RTU / Modbus-ASCII) RS485 and SDI-12communication protocols, has built-in calibration and compact dimensions. It can be used for indoor and outdoor environment. It is used in agriculture, greenhouses, industrial ventilation systems or transport stations, as well as in projects that require the determination of CO2 levels.
Features
- High performance: accuracy, fast response and excellent stability
- MODBUS, RS485 and SDI-12 support
- Compact probe dimensions of 110 x 50 x 35 mm
- User-friendly and ready-to-use: fully calibrated, easy to install and integrate
- Power supply from 5 V to 16 V
- Wide measuring range and high accuracy: from 400 ppm to 5000 ppm, ±(50 ppm + 5% * MV)
Wide range of applications
- Smart agriculture
- Smart cities
- Construction of ventilation systems
- Industrial ventilation systems
- Airport, train station, shopping mall, home, office or classroom
- Laboratory, warehouse and other places to monitor CO2 levels
Connection diagram
The sensor comes with a cable that is terminated with 6 leads. It should be connected to Raspberry Pi andArduinousingGrove RS485converter according to following markings:
- Yellow - RS485+ / A / T+
- Green - RS485- / B / T-
- Red - VCC+
- Black - VCC- (GND)
- Blue - SDI-12 5 V
- White - SDI-12 3.3 V
Product is compatible with Arduino and Raspberry Pi. |
Technical specification
CO2 |
|
---|---|
Measuring range | from 400 ppm to 5000 ppm |
Accuracy | ± (50 ppm + 5% x MV) (in the range from 400 ppm to 3000 ppm) |
Distribution | 1 ppm |
General Specifications | |
Model | SOLO CO2 5000 |
Interface | RS485 |
Protocol | Modbus-RTU RS485 / Modbus-ASCII RS485 / SDI-12 (v1.4) |
Response time (T90) | <5 minutes="" for="" a="" typical="" 90="" step="" change="" td=""> |
IP class | IP x 5 (PTFE filter is not waterproof) |
Working temperature | From -10°C to +50°C |
Permissible humidity during operation | 0% to 85% (non-condensing) |
Cable length | 2 m |
Probe dimensions | 110 x 50 x 35 mm |
Weight | 300 g |
MODBUS RS-485 | |
Power supply | 5 V to 16 V |
Current consumption |
|
Time to prepare for work | approx. 120 s |
Scan frequency | 1 s |
Response time | ≤ 4 ms |
SDI-12 | |
Power supply | 5 V to 16 V |
Current consumption (sleep mode) |
|
Current consumption (active mode) |
|
Warm-up time | 15 ms |
Scan Interval | 120 s |